Wire draw encoders
HighLine
Type BTF13-A1AM1020
Part No. 1034301
At a glance
Absolute wire draw encoders
Modular measuring system with a wide selection of interfaces/measuring lengths
Measuring lengths: 2 m ... 50 m
Very rugged system (dirt wiper, integrated brushes), highly shock and vibration resistant
High-quality winding mechanism and wire input
Interfaces: - ANALOG, SSI, PROFIBUS, CANopen, DeviceNet, HIPERFACE®
High enclosure rating
High resolution possible
Your benefits
Reliable solution in harsh environments
Long service life due to rugged industrial housing
Quick and easy installation without the need for precise linear guidance
Low integration and maintenance costs
Customization option reduces storage costs
No reference run necessary thanks to the absolute measuring principle
Teach-in function enables fast commissioning
Performance
Measuring range: 0 m ... 10 m
Repeatability: ≤ 1.5 mm 1)
Linearity: ≤ ± 2 mm 2)
Hysteresis: ≤ 3 mm 3)
Resolution (wire draw + encoder): 0.05 mm 4) 5)
1) 3) Value refers to wire draw mechanism 2) 4) 5)
Mechanical data
Mass (including encoder): 4 kg
Mass (mechanics): 3.5 kg
Measuring wire diameter: 1.35 mm
Measuring wire material: Highly flexible stranded steel 1.4401 stainless steel V4A
Housing material, wire draw mechanism: Aluminum (anodised), plastic
Spring return force: 10 N ... 20 N 1)
Life of wire draw mechanism: 1 million cycles 2)
Actual length of cable extension: 10.2 m
Wire acceleration: 40 m/s2
Operating speed: 4 m/s
Mounted encoder: ATM60 SSI
Mounted mechanic: MRA-F130-110D2
Part number mechanic: 6028627
Part number encoder: 1034294
Mass (measuring wire): 7.1 g/m
Length of wire pulled out per revolution: 334.1 mm 3)
Number of steps per revolution: 6,680
1) These values were measred at an ambient temperature of 25 °C. There may be variations at other temperatures. 2) 3)
Electrical data
Initialization time: Ca. 1,050 ms 1)
Supply voltage: 10 V ... 32 V
Code type: Gray
Power consumption: 0.8 W
MTTFd: mean time to dangerous failure: 150 a 2) 3)
1) Valid positional data can be read once this time has elapsed. 2) This product is a standard product and does not constitute a
safety component as defined in the Machinery Directive.
Calculation based on nominal load of components, average ambient
temperature 40°C, frequency of use 8760 h/a. All
electronic failures are considered hazardous. For more information, see document no. 8015532. 3) The value applies to the mounted encoder
Interfaces
Electrical interface: SSI
Connection type: Connector M23, 12-pin, radial
Clock frequency: 1 MHz
SET (electronic adjustment): Via SET cable
Encoder: Absolute encoders
Ambient data
EMC: (according to EN 61000-6-2 and EN 61000-6-3)
Enclosure rating encoder: IP 67
Enclosure rating mechanic: IP 64
Resistance to shocks: 10 g, 6 ms (according to EN 60068-2-27)
Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Relative humidity / Condensation: 90 % (condensation of the optical scanning not permitted)
Working temperature range (encoder): -20 °C ... +70 °C
Working temperature range (mechanics): -30 °C ... +70 °C
Working temperature range (combination): Wird definiert durch den h?heren mininalen und niedrigeren maximalen Wert des Arbeitstemperaturbereichs von Encoder und Mechanik