欧美成人精品不卡在线观看,年轻的母亲4电影在现线兔费,欧美国产日韩一区二区三,国产日韩欧美精品欧美精品

上海銳譽(yù)實(shí)業(yè)有限公司

DOLD多德

BG5925.02/101/60 DC24V	0058929
上海銳譽(yù)訂購

BG5925.02/101/60 DC24V 0058929

型 號:BG5925.02/101/60 DC24V
品 牌:DOLD多德
價(jià)格-貨期:請咨詢我司商務(wù)
電 話:021-50189957
郵箱:??rymro@sina.com
BG5925.02/101/60 DC24V產(chǎn)品詳細(xì)信息:

 BG5925.02/101/60 DC24V 0058929急停模塊DOLD模塊,上海銳譽(yù)為你提供,歡迎咨詢;

 急停模塊的功能就是當(dāng)一個(gè)潛在的危險(xiǎn)即將發(fā)生之前,可以快速可靠的阻止該危險(xiǎn)的發(fā)生。因此必須在急??刂蒲b置里集成一個(gè)特定的安全電路,以防止設(shè)備故障的產(chǎn)生。根據(jù)風(fēng)險(xiǎn)評估系統(tǒng)與安全級別的要求,這些安全電路的設(shè)計(jì)必須符合以下要求:

* 安全冗余
* 循環(huán)監(jiān)控
* 故障之后安全操作

高端功能

* 帶強(qiáng)制導(dǎo)向觸點(diǎn)的輸出
* 符合EN 954標(biāo)準(zhǔn)

應(yīng)用場合:塑機(jī),機(jī)床等

安全認(rèn)證:TUV,BG,UL

觸點(diǎn)形式:2常開,4常開,3開1閉

產(chǎn)品選型:

功能 Also suited as
safety gate monitor Safety category
acconting to
EN 954-1 1) Performance Level
to EN 13849-1 1) SIL Claimed Level
EN 62061 1) 1-channel/
2-channel Output contacts, max. Breaking current Ith [A] max. cross fault
detection nominal voltage Detachable terminals width [mm] Type

 
 
 
 
 
 
 
 
 DC AC 
 
 
Emergency stop module 3) 
 4 d 2 1 4NO 5 A 
 + + + 22.5 LG5924
Emergency stop module 3) + 4 e 3 1; 2 4NO 5 A + + + + 22.5 LG5925
Emergency stop module 
 4 e 3 1 4NO 7 A 
 + + + 22.5; 70 BG5924, IP5924
Emergency stop module,
most compact design 
 4 e 3 1 1NO 5 A 
 + 
 
 17.5 RK5942
Emergency stop module + 4 e 3 1; 2 2NO 10 A + + + 
 45 BD 5987
Emergency stop module + 4 e 3 1; 2 3NO 7 A + + + + 22.5 BG5925
Emergency stop module + 4 e 3 1; 2 3NO, 1NC 10 A 
 + + 
 100 BN5983
Emergency stop module + 4 e 3 1; 2 3NO, 1NC 10 A + + + 
 45 BD 5935
Emergency stop module 3)
with delay up to 300s + 
 e 3 1;2 2NO, 1NO
contact delayed 8 A + + 
 + 22.5 LG5928
Emergency stop module
with delay up to 300s + 4 e 3 1; 2 3NO, 3NO
contact delayed 5 A + + 
 + 45 BH5928
Emergency stop module
with delay up to 300s + 4 e 3 1; 2 3NO, 3NO
contact delayed 5 A + 
 + + 67.5 BI5928
Emergency stop module
with power failure detection 
 4 e 3 1; 2 3NO 5 A + 
 + + 90 BH 5903
Emergency stop module
with power failure detection 
 4 e 3 1; 2 3NO 5 A + 
 + + 90 BL 5903
Emergency stop module + 4 e 3 1; 2 3NO, 1NC 10 A + 
 + 
 100 BN 5930.48/203,
BN 5930.48/204

NO = normally open contact, NC = normally closed contact , NO contact delayed
For multiple monitored emergency-stop buttons in combination with further safety functions see SAF.masterC and SAF.masterM
1) Please check state of approval of idividual devices in the latest data sheet.
2) Safety data on request
3) With varable Terminals
S = screw terminals
PS = removable screw terminals
PC = removable cage clamp terminals

Following product are also available:

BN 5930.48,BO 5988.61,BO 5988.47